Protein adsorption and functional hybrid carriers

Equipment

Nicolet™ iS50 FTIR Spectrometer with Smart SAGA™ Accessory

Specifications: 

  • Laser: HeNe
  • Spectral Range: 15 to 27,000 cm-1
  • Spectral Resolution: Better than 0.09cm1

 

Featuring Smart SAGA™ (Specular Apertured Grazing Angle) Accessory for use with ultra-thin coatings; Absorbed species on metal substrates; Lubricants; Surface contaminants; Residues; Molecular Monolayers

https://www.thermofisher.com/order/catalog/product/0033-199

 

Circular Dichroism (CD) Jasco J-1500

Specifications:

  • Three single-position Peltier thermostatted cell holders

  • The scanning emission monochromator (FMO-522) and emission detector

    (FDT-538)

  • Automated Titration (ATS-530)

Surface Plasmon Resonanse – BioNavis SPR NaviTM 200

Specifications:

  • Wavelenght of light: 670 – 785 nm

  • Optical channels: 2

  • SPR angle scanning range: 40˚ – 78˚

  • Refractive index range for the running buffers: 1.00 – 1.45

Quartz Crystal Microbalance with Dissipation Monitoring (QCM-D) Q-Sense E1

Specifications:

  • Maximum mass sensitivity in liquid: ~ 0.5 ng/cm2 (5 pg/mm2)

Q-sensors specifications:

  • Frequency: 4.95 MHz ± 50kHz

  • Cut: AT

  • Size: Diameter 14 mm, thickness: 0.3 mm

  • Flow and window module

Autolab PGSTAT302N potentiostat

Specifications:

  • Potential range: -10 V to 10 V
  • Compliance voltage range: ± 30 V
  • Maximum current in ampère: ± 2
  • Number of current ranges: 9
  • Number of current ranges remarks: 10 nA to 1 A
  • Maximum number of modules: 8
  • Current resolution: 0.0003% 
  • Maximum bandwidth: 1 Hz
MALVERN ZETASIZER NANO ZS

Particle size and molecular size:

  • Measurement range: 0.3nm – 10.0 microns* (diameter).
  • Measurement principle: Dynamic Light Scattering
  • Minimum sample volume: 12µL
  • Accuracy: Better than +/-2% on NIST traceable latex standards
  • Precision / Repeatability: Better than +/-2% on NIST traceable latex standards
  • Sensitivity: 0.1mg/mL (Lysozyme)
Evolution™ 201 UV-Visible Spectrophotometer

Specification:

Accuracy (Photometric) 0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST

Certifications/Compliance: ISO 9001:2008

Detector Type: Dual Silicon Photodiodes

Display: None

Photometric Accuracy Instrument: 1A: ±0.006A

2A: ±0.010A

Measured at 440 nm using calibrated neutra

Wavelength Accuracy: ±0.5 nm  (541.9, 546.1 nm mercury lines); ±0.8 nm (full range 190 to 1100 n

AXIO IMAGER Z1m MICROSCOPE ZEISS

Specifications:

  • Objectives: A-Plan 10x/0.25 Ph1 M27, A-Plan 40x/0.65 Ph2 M27, EC Epiplan-Neofluar 20x/0.50 HD DIC M27, EC Epiplan-Neofluar 50x/0.80 HD DIC M27

DENSITY METER Anton Paar DMA 5000M MICROVISCOMETER Anton Paar Lovis 2000ME

Measuring range:

  • Dynamic viscosity 0.3 mPa·s to 10 000 mPa·s
  • Inclination 15° to 80° inclination in 1° steps
  • Density 0 g/cm3 to 3 g/cm3

Temperature range:

  • Viscosity measurement +5 °C to 100 °C
  • Density measurement 0 °C to 95 °C
Refractometer ATAGO

Specifications:

  • Model Table top model RX-5000α
  • Accuracy 1%
  • Temperature range 20-60 °C
  • Measurement time 3 sec
  • Brix Value 0-100%
  • Measure refractive index samples from 1.32500 to 1.70000
Buchi Vacuum Pump V700

V-700 Vacuum Pumps System sound absorber, vacuum tubing and connections and operating instructions.

Contact us via the contact form